Triplett Meters
From InterceptRadio.com Wiki
(Difference between revisions)
m (→630) |
m (→630) |
||
(5 intermediate revisions not shown) | |||
Line 60: | Line 60: | ||
| align="right"| 600 | | align="right"| 600 | ||
| align="right"| 120mA | | align="right"| 120mA | ||
- | | | + | | align="right"| 60uA |
| x | | x | ||
| | | | ||
Line 154: | Line 154: | ||
| | | | ||
| | | | ||
+ | |- | ||
+ | | 630-L | ||
+ | | | ||
+ | | Jewl | ||
+ | | 5000/1000 | ||
+ | | align="right"| 10A | ||
+ | | 100uA | ||
+ | | | ||
+ | | | ||
+ | | banana probes | ||
|- | |- | ||
| 630-L type 2 | | 630-L type 2 | ||
Line 166: | Line 176: | ||
|- | |- | ||
| 630-M | | 630-M | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
| | | | ||
+ | | Jewl | ||
+ | | 6000/1200 | ||
+ | | align="right"| 12A | ||
+ | | 120uA | ||
+ | | x | ||
+ | | x | ||
| 1Meg/Volt sens. | | 1Meg/Volt sens. | ||
|- | |- | ||
| 630-M type 1 | | 630-M type 1 | ||
| | | | ||
- | | | + | | Jewl |
- | | | + | | 6000/1200 |
- | | | + | | align="right"| 12A |
- | | | + | | 120uA |
| | | | ||
| | | | ||
Line 187: | Line 197: | ||
| 630-NA | | 630-NA | ||
| | | | ||
- | | | + | | Jewl |
| 6000/1200 | | 6000/1200 | ||
| align="right"| 12A | | align="right"| 12A | ||
- | | | + | | 120uA |
| x | | x | ||
| x | | x | ||
Line 343: | Line 353: | ||
| x | | x | ||
| | | | ||
- | | | + | | model 3050 |
|- | |- | ||
| 630-PLK | | 630-PLK | ||
Line 366: | Line 376: | ||
|- | |- | ||
| 630-PLK type 8 | | 630-PLK type 8 | ||
+ | | | ||
+ | | Taut | ||
+ | | align="right"| 1000 | ||
+ | | align="right"| 10A | ||
+ | | 100uA | ||
+ | | x | ||
+ | | | ||
+ | | banana probes | ||
+ | |- | ||
+ | | 630-PLK type 9 | ||
| | | | ||
| Taut | | Taut |
Current revision as of 15:21, 26 June 2013
Triplett is a manufacturer of electronic test equipment, most notably the 310 and 630 VOM's.
630
The 630 is a well known VOM manufactured from 1949? to 2007. Its primary competetion was the Simpson 260.
Model | Years | Mvmt | PeakV | PeakA | LowA | Mirror | Doubler | Notes |
630 | 1949-? | Jewl | 6000/1200 | 12A | 60uA | banana probes | ||
630 type 3 | Susp | 6000/1200 | 12A | 100uA | 20K/v. banana probes | |||
630 type 4 | Jewl | female banana probes | ||||||
630 type 4 | Susp | 600 | 120mA | female banana probes | ||||
630 type 5 | Jewl | 600 | 120mA | 60uA | x | female banana probes | ||
630 type 5 | Taut | 600 | 120mA | x | aka model 3030. 30v(413/210) battery. female banana probes | |||
630 type 6 | 2007? | Taut | 600 | 120mA | 300uA | x | aka model 3030. female banana probes | |
630-A | 1953-? | Jewl | 6000/1200 | 12A | 60uA | x | 30v(413/210) battery. banana probes | |
630-A type 2 | Susp | 6000/1200 | 12A | 60uA | x | banana probes | ||
630-A type 3 | x | |||||||
630-APL | 1970-? | 5000/1000 | 10A | 100uA | x | banana probes | ||
630-APL type 4 | Susp | 5000/1000 | 10A | 100uA | x | banana probes | ||
630-APL type 5 | 1980? | 30v(413/210) battery | ||||||
630-APLK | -1976? | Jewl | 5000/1000 | 10A | 100uA | x | ||
630-L | Jewl | 5000/1000 | 10A | 100uA | banana probes | |||
630-L type 2 | Jewl | 5000/1000 | 10A | 100uA | banana probes | |||
630-M | Jewl | 6000/1200 | 12A | 120uA | x | x | 1Meg/Volt sens. | |
630-M type 1 | Jewl | 6000/1200 | 12A | 120uA | ||||
630-NA | Jewl | 6000/1200 | 12A | 120uA | x | x | banana probes | |
630-NA type 1 | banana probes | |||||||
630-NA type 2 | 5000/1000 | 10A | banana probes | |||||
630-NA type 3 | Susp | 6000/1200 | 12A | 120uA | x | x | 30v(413/210) batt. Some 6000(Red)/1200,others 1200 only. banana probes. #3042? | |
630-NA type 4 | Susp | 1200 | 12A | 120uA | x | x | banana probes | |
630-NS | 200K/v instead of 20K/v sens. banana probes | |||||||
630-NS type 2 | Susp | 6000/1200 | 12A | 120uA | x | x | 200K/v instead of 20K/v sens. banana probes | |
630-NS type 3 | Susp | 1200 | 12A | 120uA | x | x | 200K/v instead of 20K/v sens. banana probes #3102 | |
630-PL | 1976-? | Jewl | 5000/1000 | 10A | 100uA | banana probes | ||
630-PL type 2 | 5000/1000 | 10A | 100uA | banana probes | ||||
630-PL type 3 | 5000/1000 | 10A | 100uA | some? | banana probes | |||
630-PL type 4 | Susp | 5000/1000 | 10A | 100uA | banana probes | |||
630-PL type 5 | 1980? | Susp | 1000 | 10A | 100uA | 30v(413/210) battery. banana probes | ||
630-PL type 5 | x | |||||||
630-PL type 6 | 600 | 120mA | x | |||||
630-PL type 6 | Taut | 1000 | 10A | x | model 3050 | |||
630-PLK | -1976? | 5000/1000 | 10A | 30v(413/210) battery. banana probes | ||||
630-PLK type 7 | Susp | 1000 | 10A | 100uA | banana probes | |||
630-PLK type 8 | Taut | 1000 | 10A | 100uA | x | banana probes | ||
630-PLK type 9 | Taut | 1000 | 10A | 100uA | x | banana probes |
- A = higher precision than non-A
- S = very high sensitivity (200K/v)
- M = super high sensitivity (1M/v)
- L = low power ohms
- N = includes range doubler switch
- P = polarity reversal switch ?
- K = protection circuit
- APL = higher precision than A + low power ohms
- PLK = protection circuit
- APLK = both the above
- PL = all the above (1976 and later)
- Some information sourced from postings by Fred Scoles